| Series | Model No. | Output Watts | Input Voltage | Input range | Polarity Protection | Output Voltage |
| 12 | STC-1240005 | 400W continuous | ±12V DC | ±9V ~ ±18V DC | No | +5V DC |
| 12 | STC-1255012 | 550W continuous | ±12V DC | ±9V ~ ±18V DC | No | +12V DC |
| 12 | STC-1265024 | 650W continuous | ±12V DC | ±9V ~ ±18V DC | No | +24V DC |
Output Voltage: XX (X=0~9)
| ENVIRONMENTAL CONDITIONS: | |
| ● Cooling: Forced Air-cooling, | 80x80x25 mm Fan x 1 (with 2 Ball Bearings) |
| ● Fan brand: | DELTA, NMB, SUNON. Specifications are equivalent |
| ● Operating Temperature: | 0°C ~ +50°C (-20°C~+60°C H version is optional) Full Load |
| ● Operating Humidity: | 20%~85% RH. (Non condensing) |
| ● Storage Temperature | -20°C~+80°C |
| ● Storage Humidity: | 10%~90% RH. (Non condensing) |
| ● Operating Altitude | 10M Below Sea level and 3000M Above Sea level |
| DC INPUT CHARACTERISTICS: | |
| ● Input connector type | 85A/600V 2-Pin M5 Nickel Plated steel Terminal |
| ● Input connector type | Make sure to plug the power source according to the label instruction |
| ● Input Current | 28.8A / 57.7A (400W) 39.7A / 79.4A (550W) 46.9A / 93.8A (650W)
@ Full Load High Line & Low Line |
| ● Inrush Current, less than | 100A (400W) 120A (550W) 150A (650W) @ Cold start @25°C ambient |
| DC OUTPUT CHARACTERISTICS: | |
| Output Voltage | Regulation | Output Current | Ripple & Noise | |||||||
| Load | Line | Cross | 400W | 550W | 650W | |||||
| Min | Max | Min | Max | Min | Max | |||||
| +5V | ±5% | ±1% | ±5% | 0A | 80A | 0A | 80A | - | - | 50mV |
| +12V | - | - | 0A | 45.8A | - | - | 120mV | |||
| +24V | - | - | - | - | 0A | 27A | 240mV | |||
| OVERALL PERFORMANCE: | |
| ● Efficiency | 70% @ 12V typical @ Full Load |
| ● Short Circuit Protection (SCP) | All output equipped with SCP (shutdown and latch off) |
| ● Over Power Protection (OPP) | Peak power protected to 130%±10% of continuous rated power (shutdown and latch off) |
| ● Over Voltage Protection (OVP) | |
| RELIABILITY: | |
| ● MTBF (Mean Time Between Failure): | >100 000 hours @max. Load, 25°C ambient |
| ● Safety Standards | Meet IEC 60950-1, EN 60950-1 |
| ● Safety Approved | |
| ● EMI Compatibility (EMC) Standard | EN 55032:2015/AC:2016, CISPR 32:2015, EN 6100-3-2:2014, |
| EN 6100-3-3:2013, EN 55024:2010 +A1:2015 | |
| ISOLATION:
|
|
| ● INPUT and OUTPUT are isolated by transformers and optical couplers | |
| ● Dielectric Withstand: | 12V: INPUT to OUTPUT & INPUT to frame GND: 1.0kV DC for 60sec |
| ● Leakage Current: | <0.005μA @ 12V DC |
| Output Connector specific: | |
| ● Terminal Block | |
| PCB specific: | |
| ● 2 layer | |
| ● Copper: 3 Oz each layer | |
| ● Thickness: 1.6 mm | |
| ● Material: FR4 | |
| ● PCB material origin: Taiwan | |
| Power chassis Dimension: | |
| ● 140(L) x 150(W) x 86(H) mm / 5.51(L) x 5.9(W) x 3.37(H) Inches | |
| Net Weight: | |
| ● 2.6 kg / 5.73 lbs | |
| Gross Weight: | |
| ● 3 kg / 6.61 lbs | |
| Packing Detail | |
| ● 8 pcs / GW 20.6 kg | |
| Measurement of Carton | |
| ● 46 x 41 x 30 cm / 0.0566 m3 / 2 Cuft | |
Input terminal picture for 140mm chassis length:
Output terminal picture for 140mm chassis length:
Input terminal picture for 184mm chassis length:
DOWNLOAD_specification_STC-12650XX.pdf
DOWNLOAD_chassis drawing_STC-XX600XX_D2D-184-20200219
DOWNLOAD_chassis drawing_stc-d2d-184dd-20230906.pdf
DOWNLOAD_chassis drawing_stc-dtd-140_XX-20250220.pdf