12
|
STC-122200XX
|
2200W continuous
|
±12V DC
|
±9V ~ ±17V DC
|
No
|
24
|
STC-242400XX | 2400W continuous
|
±24V DC
|
±18V ~ ±35V DC | No |
48
|
STC-482500XX | 2500W continuous
|
±48V DC
|
±36V ~ ±59V DC | No |
120
|
STC-1202500XX
|
2500W continuous
|
±120V DC
|
±90V ~ ±145V DC | No |
Output voltage: XX (X=0~9)
ENVIRONMENTAL CONDITIONS: |
|
● Cooling: Forced Air-cooling, |
80x80x25 mm Fan x 2 (With Two Ball Bearing) |
● Fan brand: |
DELTA, NMB, SUNON, SUNON IP68 (for H version).
Specifications are equivalent |
● Operating Temperature: | 0°C ~ +50°C Full Load |
● Operating Humidity: | 20%~85% RH. (Non condensing) |
● Storage Temperature | -20°C~+80°C
|
● Storage Humidity:
|
10%~90% RH. (Non condensing) |
● Operating Altitude | 10M Below Sea level and 3000M Above Sea level |
|
|
DC INPUT CHARACTERISTICS: |
|
● Input connector type | 25A/300V UL Approved 3-Pin Terminal
|
● Input connector type | Make sure to plug the power source according to the label instruction |
● Input Current
|
153A/305A @12V, 80A/151A @24V, 48A/80A @48V, 19A/30A @120V
|
● Inrush Current
|
Less than 350A @12V, 250A @24V, 120A @48V, 60A @120V
@Cold Start @25°C |
DC OUTPUT CHARACTERISTICS:
|
|
Output Voltage |
Regulation status |
Output Current table
|
Ripple & Noise |
|||||||
Load |
Line |
Cross |
2200W |
2400W |
2500W |
|||||
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
|||||
5V |
±5% |
±1% |
±5% |
0A |
440A |
0A |
480A |
0A |
500A |
50mV |
12V |
0A |
183,33A |
0A |
200A |
0A |
208,33A |
120mV |
|||
24V |
0A |
91,66A |
0A |
100A |
0A |
104,16A |
240mV |
|||
48V |
0A |
45,83A |
0A |
50A |
0A |
52,08A |
480mV |
|||
120V |
0A |
18,33A |
0A |
20A |
0A |
20,83A |
1200mV |
OVERALL PERFORMANCE: | |
● Efficiency | 70% typical @ 12V, 80-85% @ 24V, 48V, 90% @ 120V DC Full Load |
● Short Circuit Protection (SCP)
|
All output equipped with SCP (shutdows and latch off)
|
● Over Power Protection (OPP) | Peak power protected to 130%±10% of continuous rated power |
|
(shutdown and latch off)
|
● Over Voltage Protection (OVP) |
|
|
|
RELIABILITY: |
|
● MTBF (Mean Time Between Failure): | >100 000 hours @max. Load, 25°C ambient
|
● Safety Standards | Meet IEC60950-1, EN60950-1 |
● Safety Approved |
|
● EMI Compatibility (EMC) Standard | EN55032:2015/AC:2016, CISPR32:2015, EN6100-3-2:2014, |
|
EN6100-3-3:2013, EN55024:2010 +A1:2015 |
|
|
ISOLATION:
|
|
● INPUT and OUTPUT are isolated by transformers and optical couplers
|
|
● Dielectric Withstand: | 12V, 24V: INPUT to OUTPUT & INPUT to frame GND: 1.0kV DC for 60sec |
● Dielectric Withstand: | 48V: INPUT to OUTPUT & INPUT to frame GND: 2.0kV DC for 60 seconds |
● Dielectric Withstand: | 120V: INPUT to OUTPUT & INPUT to frame GND: 2.5kV DC for 60 seconds |
● Leakage Current: | <0.005μA @ 12V, 24V, 48V, 120V DC |
|
|
Output Connector specific:
● Terminal Block
PCB specific:
● 4 layer
● Copper: 3 Oz each layer
● Thickness: 1.6mm
● Material: FR4
● PCB material origin: Taiwan
Power chassis Dimension:
● 638.5(L) x 170(W) x 100(H) mm / 25.137(L) x 6.69(W) x 3.937(H) Inches
Net Weight:
● 5.2 kg / 11.46 lbs
Gross Weight:
● 6.3 kg / 13.89 lbs
Packing Detail
● 2 pcs
● 12.7 kg / 27.99 lbs
Measurement of Carton
● -
DOWNLOAD_specification_STC-XX2500XX.pdf
DOWNLOAD_chassis drawing_STC-XX2500XX_D2D-595-20200219.pdf